DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-685HYB-LINE (Hybrid Line)
3
This section refers only to the HYB-LINE (Hybrid Line) maintenance that is
performed. Please note that the HYB-LINE (Hybrid Line) maintenance is closely
related to, and interacts with, the HYB-BD (Hybrid Line circuit pack) maintenance
in some instances. Some of the results of maintenance testing of the Hybrid Line
may be affected by the health of the Hybrid Line circuit pack. This interaction
should be kept in mind when investigating the cause of reported Hybrid Line
problems.
There are instances in this section where "service states" of a station are
mentioned. It is helpful to understand what is meant by the different service
states that may exist. An explanation of these service states follows:
Out-of-Service–The port, and thus the station, have been removed from
service. A busyout of a port causes it to be out-of-service.
Ready-for-Service–Once a port on the circuit pack has been put into
service, the voice terminal must communicate that it is present. The time
between these two events is the time when the terminal is in the
ready-for-service state.
In-Service–Once the system has received a message from the voice
terminal communicating that it is present, the station is put into the
in-service state. The terminal can also be forced into the in-service state if
it goes off-hook while it is in the ready-for-service state.
When the
status station
command has been run, and the status screen
appears, the status is reported as either out-of-service or in-service, which mean
exactly as stated in the above list, or disconnect, which means the station is in
the ready-for-service state.
Hardware Error Log Entries and Test to Clear
Valu es
Table 3-288. Hybrid Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1 (a) Any None WARNING OFF
15 (b) Any Hybrid Audits Test
(#61)
18 (c) 0 busyout port
PCSSpp
WARNING OFF release port PCSSpp
130 (d) None WARNING ON test port PCSSpp sh
257 (e) 40988 None MIN/WRN
2
OFF
Continued on next page