3-760LOG-SVN (Login Security Violation)
3
3
LOG-SVN (Login Security Violation)
The Security Violation Notification (SVN) feature provides notification when the
number of failed attempts to access the system administration/maintenance
interface meets or exceeds customer administered threshold parameters.
A major alarm is logged whenever a security violation is detected involving a
services login ID and that login ID has been disabled as a result of the security
violation. The capability to disable a login ID following detection of a security
violation involving that login ID is administrable on a per login ID basis.
Refer to
DEFINITY Enterprise Communications System Administrator’s Guide
for
information on administration required for the Security Violation Notification
feature and the option to disable a login ID following detection of a security
violation involving the affected login ID.
Hardware Error Log Entries and Test to Clear
Valu es
General Information about log-svn Error Log
Entries
a. The number (1 - 15), that appears in the error type field, corresponds to
the location the login in the internal login data structure.
b. The
Alt Name
field on the alarm report indicates the login ID associated
with the security violation and major alarm.
c. These errors/alarms are associated with a number of failed attempts to
access the system management/maintenance interface using a services
login ID that meet or exceed the customer administered threshold
parameters. The associated alarm is immediately raised as a major alarm.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1. Where <login ID> is the services login ID for which the security violation was detected. The Alt
Name
field indicates the login ID associated with the security violation and the major alarm.
Full Name of MO
LOG-SVN MAJOR enable login <login ID> Login Security Violation
Table 3-319. Hardware Error Log Entries and Test to Clear Value
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
1-15 None None Major OFF enable login <login ID>