Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-874PE-BCHL (PRI Endpoint Port)
3
b. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate the associated
errors (if any).
c. The PRI Endpoint Port has been busied out by a
busyout pri-endpoint
<extension>
command or by a
busyout port <PCSSpp>
command. No
wideband calls can be made to this port (although wideband calls can still
be made to other ports within this PRI Endpoint if others ports are in
service).
d. The far-end terminal adapter changed its ISDN
service
state to either
"out-of-service" or "maintenance." This may be a temporary condition due
to the testing of this port by the far-end terminal adapter
or
by a hardware
problem with the port. Outgoing calls to the terminal adapter are not
allowed over the port (although calls can still be made to other ports that
are in service within the same PRI Endpoint). To investigate the status of
the port, issue the
status pri-endpoint <extension>
command.
e. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
f. This error type indicates a disagreement between this switch and the
terminal adapter at the other end of the connection with regard to the
ISDN service state of the PRI Endpoint Port. This switch tries to recover by
performing a service state audit. The
status pri-endpoint <extension>
command can be used to determine the state of the port.
When running the Short Test Sequence, pay close attention to the results
of the Service State Audit Test (#256).
g. This port is not recognized by the far-end terminal adapter. Investigate the
PRI Endpoint administration for both the switch and the terminal adapter
and make changes as necessary.
h. The Conference Circuit Test (#7) failed on this port. See Test #7 for the
repair procedures.
i. The NPE Crosstalk Test (#6) failed on this port. See Test #6 for the repair
procedures.
j. This error indicates a failure of the UDS1 Interface circuit pack. When
running the Short Test Sequence, the results of the Signaling Link State
Check Test (#255) are important.
k. Two Service State Audit attempts have failed (see Test #256). The port is
not usable for any outgoing calls to the terminal adapter (although
incoming calls from the terminal adapter are accepted over this port, other
ports in the PRI Endpoint can still be used for both incoming and outgoing
calls to and from the terminal adapter) until the test passes and the port
state is changed to in-service (use the
status pri-endpoint <extension>
command to investigate the port status).