DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1140TONE-PT (Tone Generator)
3
Notes:
a. A failure in the tone generation facility on the indicated circuit pack has
been detected. Replace the circuit pack. See ‘‘How to Replace a
Tone-Clock Circuit Pack’’ in the TONE-BD section.
b. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
c. The tone generation facility is having problems verifying that tones have
been connected as requested.
d. The tone generation facility may or may not be able to generate tones.
e. Infrequent errors, at a rate which does not bring up an alarm, probably do
not affect service, unless there are customer complaints of no tones, or
incorrect tones which can not be explained in any other way. However, if
an alarm is raised because this error is being repeatedly logged, then the
circuit pack should be replaced. See ‘‘How to Replace a Tone-Clock
Circuit Pack’’ in the TONE-BD section.
513(d,e) 17666 Tone Generator
Audit/ Update Test
(#41)
MINOR ON test tone-clock PC r 3
769 Any Transmission Test
(#40)
MAJOR/
MINOR
ON test tone-clock PC r 3
1025 Crosstalk Test
(#90)
MAJOR/
MINOR
ON test tone-clock PC l r 2
1281 Any Tone Generator
Audit/ Update Test
(#41)
MINOR ON test tone-clock PC r 3
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
Table 3-501. Tone Generator Error Log Entries — Continued
Error
Typ e
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page