DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-73AN-LN-PT (Analog Line Port)
3
Error log entries and test to clear values
Notes:
a.
Error Type 1
: these are in-line errors and can only be resolved over time.
■ Aux Data 40960 indicates that too many simultaneous incoming
ringing attempts were made on this board. Only 4 ports on a board
may ring simultaneously. A 5th incoming call will cause an inline
error from the board.
Table 3-29. Analog line error log entries
Error
Type
Aux
Data
Associated
Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1(a) 40960
40975
40977
none
15(b) Any Audits and
Updates Test
(#36)
18 0 busy station
extension
WRN ON release station extension
130(c) None WRN ON test port UUCSSpp sh
257(d) 40973 none
513(e) Station
Present Test
(#48)
WRN OFF test port UUCSSpp sh r 2
769 Battery Feed
Test (#35)
MIN/
WRN
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
ON test port UUCSSpp sh r 2
1025 Looparound
Test (#161)
MIN/
WRN
2
ON test port UUCSSpp l r 2
1281 Conference
Test (#7)
MIN/
WRN
2
ON test port UUCSSpp l r 2
1537 NPE
Crosstalk Test
(#6)
MIN/
WRN
2
ON test port UUCSSpp l r 2