Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-15busyout sp-link
2
busyout sp-link
This command places the system printer link into a maintenance busy state. No
periodic or scheduled maintenance is performed on the busied out system
printer link until it is released. Warning alarms (error type 18) are generated on
each busied out maintenance object, so that INADS can determine the state of
the object. Placing the system printer link in a busyout state blocks access to the
system printer. The
release sp-link
command reactivates the system printer link.
Output
Field descriptions
busyout station
This command places the installed and uninstalled administered voice terminal
extension (station) in a maintenance busy state. No periodic or scheduled tests
are performed on the busied out station until it is released. When the object is
maintenance busy it is deactivated (no call processing activity may include the
busied object). Warning alarms (error type 18) are generated on each busied out
maintenance object, so that INADS can determine the state of the objects. The
command,
release station
, reactivates the specified voice terminal extension.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout
sp-link
Examples:
busyout sp-link
init
inads
craft
none none
Port
Not applicable
Maintenance Name
Type of maintenance object that is busied out:
SYS-PRNT
Alt. Name
Not applicable
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
busyout sp-link SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
SYS-PRNT PASS
Command Successfully Completed