Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-114ATM Tips
1
Figure 1-42. Screen output from the show signaling routes command
Check that the
Address
field (administered using the
admin signaling
route add
command) matches those administered in DEFINITY.
3. If the A500 was administered using End System Identifiers, enter
show
signaling esi
on the A500 console. Figure 1-43
shows the command
output.
Figure 1-43. Screen output A500: show signaling esi command
Check that the
Addresses registered
(use the
admin signaling esi
add
command) match those administered in DEFINITY.
If an address or End System Identifier is missing or incorrect on the
A500 port associated with the PPN, the EAL and PACL links will
come up, but one-way talk paths may result. (The ATM network can
route from the PPN to the EPN, which creates the bidirectional EAL
and PACL signaling channels and one side of the talk path.)
If an address or End System Identifier is missing or incorrect on the
A500 port associated with the EPN, the links will not come up
between the PPN and the EPN.
A500:show signaling routes
Number of Local Static Routes Allowed: 30
Current number of Local Static Routes: 2
Address: 47.00.05.80.ff.e1.00.00.00.f2.07.2a.01.00.00.00.00.00.00.00
mask:152 cost: 0 node:self port:A1.2 state:UP
Address: 47.00.05.80.ff.e1.00.00.00.f2.07.1b.02.00.00.00.00.00.00.00
mask:152 cost: 0 node:self port:A1.1 state:UP
A500:show signaling esi
Addresses registered on A1.1
----------------------------
* 45.0001.01303538105300000000.000000000011.00
Addresses registered on A1.2
----------------------------
* 45.0001.01303538105300000000.000000000012.00