Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1011SYS-LINK (System Links)
3
Common procedure for repairing link problems
The state of a system link is dependent on the state of the various hardware
components that it travels over. To resolve any problems associated with a
system link, use the following procedure.
The switch maintains a list of hardware components over which the link travels
called the hardware path. There are two hardware paths, the current hardware
path and the faulted hardware path for each of the system links. The current
hardware path is present only for those links that are currently up. When a link is
down, the current hardware path is empty. The faulted hardware path, is always
present once the link has gone down and is
not cleared when the link
subsequently recovers.
The faulted path preserves the path that the link
traversed when it last went down. The time at which the faulted path was last
recorded is preserved and is accessible through the
status sys-link
location
and
list sys-link
commands. Therefore, the focus of attention for problems which
do not involve a link that is down, is the current hardware path. If the link is down,
faulted hardware path is the focus of attention.
The command
status sys-link
location will present the state of both the
hardware paths (current and faulted) along with the state of each of the
components in the hardware path. When analyzing any system link problem, look
for alarms on the components listed under desired hardware path. If any alarms
are present, then follow the maintenance procedures for the alarmed
components to clear those alarms first.
When all the components are alarm free, wait for 3 minutes to allow the links to
recover. Test the system link through
test sys-link PCSSpp long clear
and
notice any tests that fail. If any failures are found, fix the problems indicated by
the tests and repeat the procedure.
Error Log Entries and Test to Clear Values
Table 3-448. SYS-LINK Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
13 (a) System Link Status
(985)
WARNING OFF
257 (b) WARNING OFF test sys-link PCSSpp l cl
513 (c) WARNING OFF test sys-link PCSSpp l cl
772 (d) WARNING OFF test sys-link PCSSpp l cl
1025 (e) WARNING OFF test sys-link PCSSpp l cl
1281 (f) WARNING OFF test sys-link PCSSpp l cl
Continued on next page