DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-132ATM-BCH (ATM B-Channel Trunk)
3
Service State Audit (#256)
This test checks the service state of the trunk.
Country protocol 1.
If the interface uses country protocol 1 (includes USA), the
service-state audit executes in all trunk service states. It queries the service state
on the far end and waits 2 minutes for a reply. If the first request times out, the
service-state audit asks again. If the request times out again, it logs error 3073
and resends the request every 15 minutes. It places in-service trunks in the
MAINTENANCE/FAR-END state (outgoing calls blocked, incoming calls
accepted). Incoming calls trigger an immediate service-state audit without
waiting for the end of a 15-minute cycle.
Any other country protocol.
If the interface uses some other country protocol,
the service-state audit executes only on trunks that are in the
OUT-OF-SERVICE/FAR-END state. It asks the far-end switch to bring the trunk
back into the IN-SERVICE state and waits 2 minutes for a reply. If the first request
times out, the service-state audit asks again. If the request times out again, it
leaves the trunk in the OUT-OF-SERVICE/FAR-END state and tries again in 1 hour.
NOTE:
PASS for this test only means that a message to the far-end was
successfully sent.
To check the service state of the ATM-BCH trunk, run
status trunk
grp#
/
mbr#
.
4 FAIL Signaling channel problem
1. Look for errors or alarms against the ‘‘ATM-SGRP (ATM Signaling
Group)’’ and ‘‘ATM-DCH (ATM D-Channel Port)’’ maintenance objects.
8 FAIL TN230x circuit pack failed
1. See the ‘‘ATM-INTF (TN2305/6)’’
maintenance object.
PASS Signaling link OK.
Table 3-53. TEST #255 Signaling Link State Audit Test — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page