Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-154list testcalls
2
Detail report field descriptions
Group
The trunk group number selected.
Type
The trunk group type.
Vendor
The vendor of this trunk group.
TTL Type
The kind of test line for this trunk group.
Threshold Values
The list of marginal and unacceptable threshold values defined
on the trunk group form.
The following fields appear on the lower section of the form. Many
of the column headings contain the abbreviations “FE” for far end
and “NE” for near end. These abbreviations define which end
took the measurements.
Trk Mem
The trunk member within the trunk group.
Test Date
The month and day this trunk was tested.
Test Time
The time of day this trunk was tested.
Tst Rslt
This field describes the results of the trunk transmission test.
1004Hz-loss Min
Far-to-near and near-to-far measurements of 1004-Hz loss from
low-level tone.
1004Hz-loss Max
Far-to-near and near-to-far measurements of 1004-Hz loss at 0
dBm.
list testcalls detail grp 80 Page 1 SPE A
ATMS MEASUREMENT REPORT
Group: 80 Type: co Vendor: TTL Type: 105-w-rl
THRESHOLD VALUES Loss dev at
1004Hz-loss 404Hz 2804Hz C-msg C-ntch SRL SRL
Min Max - + - + Noise Noise LO HI ERL
Marginal -2 21 9 9 9 9 55 74 0 0 0
Unacceptable -2 21 9 9 9 9 55 74 0 0 0
Trk Test Test Test -16dBm 0dBm
Mem Date Time Rslt NE FE NE FE NE FE NE FE NE FE NE FE NE FE NE FE NE FE
1
2
3
4
5
6
7
8
9
press CANCEL to quit -- press NEXT PAGE to continue