DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-246ATM-TRK (Circuit Emulation Service Circuit Pack)
3
Table 3-107. ATM Board Reset (#1256)
Error
Code
Test
Result Description/ Recommendation
1005 ABORT Wrong circuit pack configuration to run this test. The ATM CES Trunk
Interface circuit pack provides timing for the system and cannot be reset
without major system disruptions.
1. Set synchronization to another ATM CES trunk circuit pack or to the
Tone-Clock circuit pack and test again.
1015 ABORT Test cannot be run because the ATM-TRK circuit pack has not been busied
out.
1. Busyout out the circuit pack (busyout board UUCSS).
2. Repeat the test (test board UUCSS long).
None ABORT Could not allocate the required system resources
1. Retry the command up to 5 times at 1-minute intervals.
2. If the test continues to abort escalate the problem.
2000 ABORT Sanity test timed out.
1. Wait 5 minutes. Then see if ATM-TRK circuit pack is visible to the system
by running list config all.
2. If the ATM-TRK circuit pack is visible (list configuration all), run the test
again, and escalate if the problem recurs.
3. If the ATM-TRK circuit pack is not visible to the system (list
configuration all), re-seat the ATM-TRK circuit pack, and retest.
4. If the ATM-TRK circuit pack is still not recognized by the system, replace
the board.
2100 ABORT Could not allocate required system resources
1. Retry the command up to 5 times at 1-minute intervals.
2500 ABORT Internal system error.
1. Try to reset the circuit pack (reset board UUCSS).
Continued on next page