DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-214set tone-clock
2
Field descriptions
set tone-clock
This command sets the active tone/clock for a PN that has a duplicated
tone/clock circuit pack. Technicians should reset the default active tone clock in
each PN after using the
set tone-clock
command. If it is not in use, a single
failure can cause an unnecessary service outage. The schedule maintenance
tone-clock switch option does not reset the tone-clock to the default active if it
was not active at the beginning of the test.
set vector
This command specifies restart levels for core dumps and places core dumps on
primary Mass Storage System (a tape in a tape system and core dump memory
cards in a memory card system) devices for later examination. The
set vector
command allows technicians to tailor restart levels that copy memory to primary
Mass Storage System devices.
NOTE:
Software never requests an extended reboot.
To force an immediate core dump, set the appropriate bit using this command,
then enter the
reset system
command at a level that forces core dumps
corresponding to set vector bits.
When a system restart occurs in a simplex system with the corresponding vector
bit set, the core dump writes to secondary storage (the primary MSS device).
Once the core dump writes, the vector clears and the restart executes.
Day of the Week:
Monday through Sunday
Day of the Month:
1-31; the system also checks for leap year.
Month:
January through December
Year:
1970-2999
Hour:
0-23
Minute:
0-59
Second:
The system sets this field to zero when the time of day clock is set.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
set tone-clock
location
override
Tone/clock location:
PC
Forces the set command into
effect regardless of the tone/clock
circuit pack’s health.
init
inads
craft
1 (one) none