DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-108ATM Tips
1
2. Enter
status pnc
at the DEFINITY SAT. This display tells you which
TN230X board is active in a duplicated system and how many alarms (if
any) of each severity level have been logged for the board. Figure 1-34
shows the output from this command.
Figure 1-34. Screen output for status pnc command
3. Enter either
list configuration UUC
(for the carrier in which the ATM-EI
packs reside) or
display circuit-packs
cabinet
(non-control cabinet) at
the DEFINITY SAT. This command tells you in more detail what boards are
in which slots in each cabinet and carrier. Verify that the TN230Xs are
physically located in the slots indicated on the display. Figure 1-35
shows
the output for the
display circuit-packs 1
command; Figure 1-36
shows
the output for the
display circuit-packs 2
command.
status pnc
PORT NETWORK CONNECTIVITY
Duplicated? no
Software Locked?
Standby Busied?
Standby Refreshed?
Interchange Disabled?
A-PNC B-PNC
Mode: active Mode:
State of Health: State of Health:
Inter PN Index: Inter PN Index:
Major Alarms: 0 Major Alarms:
Minor Alarms: 0 Minor Alarms:
Warning Alarms: 0 Warning Alarms: