DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-63display errors
2
Field descriptions
Error Type
Enter a specific error type. If the field is blank, the system displays
all errors. Press HELP in this field to view a list of codes.
Error List
Enter
one
of the error lists below:
active-alarms (default)
errors
cleared-errors
The title for the Hardware Error Report will include the name of the
selected error list.
Interval
Enter
one
of the codes below:
m
= last month
h
= last hour
d
= last day (default)
w
= last week
a
= all
From
Enter 2-digit numbers for the month/day/year (Example: 01/01/97).
The default is the earliest time of the existing error records in the log.
To
Enter 2-digit numbers for the month/day/year (Example: 01/01/97).
The default is the current date.
Cabinet
Enter 1
Port Network
Enter 1
Board
Number:
Board address:
PCSS
Port
Port location:
PCSSpp
Category
Enter the object code for the equipment category. Press
HELP in this
field to view a list of the object codes
display errors Page 1 of 1
ERROR REPORT
The following options control which errors will be displayed.
ERROR TYPES
Error Type: _____ Error List: active-alarms
REPORT PERIOD
Interval: _ From: __/__/__:__ To: __/__/__:__
EQUIPMENT TYPE ( Choose only one, if any, of the following )
Cabinet: __
Port Network: __
Board Number: ____
Port: ______
Category: ________
Extension: _____
Trunk ( group/member ): ___/___