DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-462DID-DS1 (DS1 DID Trunk)
3
Notes:
a. DS1 Interface circuit pack detects a hardware error. The Aux Data field
contains the Error Type: 57476, on-hook before wink; 57477, on-hook
before ready to receive digits; 57485, wink too short for valid signal.
b. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate errors (if any).
c. System Technician has busied out the trunk to out-of-service state. No
calls can be made on this trunk.
d. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
18 (c) WARNING OFF release trunk <grp>/mbr>
130 (d) None WARNING ON test trunk <grp>/<mbr>
257 (e) 57474
57473
513 (f) 57392 None MIN/MAJ
2
OFF
769 (g) 57393 None MIN/MAJ
2
OFF
1281 Conference Circuit
Test (#7)
MAJ/MIN/
WRN
3
ON test trunk <grp>/<mbr> l
1537 NPE Crosstalk Test
(#6)
MAJ/MIN/
WRN
3
ON test trunk <grp>/<mbr> l
1793 (h) ON test board PCSS l
2305(i) 50944 None MIN/MAJ
2
OFF
3840 (j) Port Audit and
Update Test (#36)
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator
field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are
out of service, then the alarm will be upgraded to a MAJOR alarm.
3. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set
options command. If the Minor alarm is not downgraded by the set options values, the Minor alarm
is upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
Table 3-196. DID-DS1 Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page