DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-41disable synchronization-switch
2
disable synchronization-switch
This command stops the automatic clock switching capability of the maintenance
subsystem. The clock refers to the oscillator on a tone/ clock or DS1 interface.
The synchronization subsystem (TDM bus clock, DS1 trunk board, and
maintenance and administration software) provides error-free digital
communication between the switch and other PBXs, COs, or customer
equipment.
disable test-number
The
disable test-number
command prohibits selected maintenance tests from
running. To run a disabled test number, enter the
enable test-number
command.
display alarms
The
display alarms command creates an Alarm Report. The user completes an
option screen to select the parameters for the report.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
disable
synchronization-
switch
init
inads
craft
none none
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
disable
test-number
number
print
schedule
Maintenance test number
Report sent to printer
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue
and is executed at the specified
time. The information displayed
by the command is sent to the
system printer instead of the
screen.
1
Examples:
disable test-number 710
disable test-number 710 print
disable test-number 510
schedule
1 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads