DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-36ANL-24-L (24-Port Analog Line)
3
Error Log Entries and Test to Clear Values
Notes:
a. These are in-line errors and can only be resolved over time.
40960 indicates that too many simultaneous incoming ringing
attempts were made on this board. Only 4 ports on a board may
ring simultaneously. A 5th incoming call will cause an inline error
from the board.
40975 indicates that the terminal equipment was on-hook when
ring-tip was detected during ringing. This usually indicates a failure
in the terminal equipment or the type of terminal has a low ringer
Table 3-15. 24-Port Analog Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port PCSSpp sh r 1
1(a) 40960
40975
40977
none
15(b) Any Audits and
Updates Test (#36)
18 0 busy-out station
extension
WRN ON release station
<extension>
130(c) None WRN ON test port PCSSpp sh
257(d) 40973 none
513(e) Station Present
Test (#48)
WRN OFF test port PCSSpp sh r 2
769 Battery Feed Test
(#35)
MIN/
WRN
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set
options command.
ON test port PCSSpp sh r 2
1025 Looparound Test
(#161)
MIN/
WRN
2
ON test port PCSSpp l r 2
1281 Conference Test
(#7)
MIN/
WRN
2
ON test port PCSSpp l r 2
1537 NPE Crosstalk Test
(#6)
MIN/
WRN
2
ON test port PCSSpp l r 2
Continued on next page