Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-376test synchronization
2
Output
The following screen is an example of the output from the
test station 81902
short
command with the assumptions that port in cabinet 1, carrier c, slot 7,
circuit 1 is an analog port and extension 81902 is connected to that port. The
responses display on a test-by-test basis with one line of data for each test result.
Field descriptions
test synchronization
This command updates all the boards with the correct synchronization source
and parameters. The system sends a downlink message to the tone clock and
DS1 boards to place them in the correct synchronization configuration, providing
error-free digital communication between the switch and other PBXs, COs, or
customer premise equipment.
Port
The port address: cabinet-carrier-slot-circuit
Maintenance
Name
The type of maintenance object that is being tested.
Alt. Name
Alternate means of identifying the maintenance object. This field
contains the extension when the object is a station.
Test No
Test being executed
Result
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test station 81902 short
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C0701 ANL-LINE 35 PASS
01C0701 ANL-LINE 48 PASS
01C0701 ANL-LINE 36 PASS
Command Successfully Completed