DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-487DID-TRK (DID Trunk)
3
updates. The port translation data includes: wink or immediate start trunk, dial
tone or rotary dialing trunk, rotary dialing inter-digit timing, Network balance
R/RC, and disconnect timing.
Table 3-204. TEST #36 Port Audit Update Test
Error
Code
Te s t
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1006 ABORT The port has been placed out of service, perhaps by craft busyout. Use the
display port PCSSpp command to determine the trunk group/member
number of the port. Use the status trunk command to determine the
service state of the port. If the service state indicates that the port is out of
service, then the port is unavailable for certain tests. You must wait until the
port is in service and idle before retesting.
1. If the port status is in service and idle, then retry the command at
1-minute intervals for a maximum of 5 times.
2100 ABORT Could not allocate the necessary system resources to run the test.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS This test passed. Translation information was successfully updated on the
circuit pack.
1. If signaling troubles are reported (Error Types 1, 257, or 513 in Error
Log table), verify translation information for this port.
2. Refer problem to the CO. If the trunk is busied out, the test does not
run, but returns PASS.
To verify that the trunk is in-service:
1. Enter status-command to verify that the trunk is in-service. If the trunk
is in-service, no further action is necessary. If the trunk is
out-of-service, continue to Step 2.
2. Enter release-trunk command to put trunk back into in-service.
3. Retry the test command.