Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-781MAPD-BD (MAPD Interface Circuit Pack TN802)
3
2. Completely remove the MAPD-BD from the system:
a. Shut down NT (see ‘‘Shutting down NT on the TN802’’
)
b. Remove any administered DS1 trunks, access endpoints, or
PRI endpoints associated with the circuit pack from their
respective trunk groups.
c. Remove the DS1 (
remove ds1 UUCSS
) and circuit pack
(
change circuit pack UUCSS
) administration.
If the circuit pack is properly administered and the red LED is still on,
follow the instructions for LED Alarms with Error Type 1 in Chapter 7.
b. Error Type 2: NT is down and the system attempts to reset the board. If the
reset fails, the board is probably bad.
1. Replace the circuit pack.
c. Error Type 18: the circuit pack has been busied out.
1. Release the board (
release board UUCSS
).
d. Error Type 23 and 1025: the MAPD-BD circuit pack is not completely
administered. In addition to insertion, the MAPD circuit pack must have all
of the following administration:
Have an entry in the circuit plan (
change circuit pack
)
Be administered as DS1 (
add ds1 UUCSS
)
The MAPD circuit pack differs from others in that inserting it into the switch
backplane is not enough to make the board usable.
e. Error Type 125, no Aux Data: A wrong circuit pack is inserted in the slot
where this circuit pack is logically administered. To resolve this problem,
either:
1. Remove the wrong circuit pack and insert the logically
administered circuit pack, OR
2. Re-administer this slot (
change circuit-pack
) to match the circuit
pack inserted.
f. Error Type 257: this error is associated with the Common Port Circuit Pack
Maintenance Test. Refer to XXX-BD (Common Port Circuit Pack)
Maintenance documentation for details.
g. Error Type 513: transient hardware problem.
Aux Data:
4352 External RAM failure
4353 Internal RAM failure
4355 Internal ROM failure