DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-653ETH-PT (Control LAN Ethernet)
3
Session Status Test (#1286)
This non-destructive test determines the status of all Ethernet port sessions. This
test queries the system software on port session status.
If the system software indicates
that: Then the switch:
All port sessions are up (ALL UP) Raises no alarm, or retires alarm
Some port sessions are up (SOME UP) Raises WARNING alarm
All port sessions are down (ALL DOWN) Raises MINOR alarm
Table 3-271. TEST #1286 Session Status Test
Error
Code
Test
Result Description/ Recommendation
1124 ABORT Ethernet link is not enabled.
1. Verify that the Ethernet link is enabled (status port UUCSSpp, status
link
n
, or display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
4. Escalate if the problem persists.
1125 ABORT Ethernet link not in service.
1. Verify whether Ethernet link is in service (status port UUCSSpp or
status link n).
2. If the Ethernet link is not in service, release the link (release link n or
release port UUCSSpp).
3. Repeat the test.
4. Escalate if the problem persists.
2000 ABORT Did not receive circuit pack test response within the allowable time period.
1. If the problem persists, reset the circuit pack (busyout board
UUCSSpp, reset board UUCSS, and release board UUCSS).
2. If the problem persists, replace the circuit pack.
2100 ABORT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
Continued on next page