DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-18Preventive Maintenance Procedures
1
Preventive Maintenance Procedures
The following preventive maintenance procedures should be followed and
logged when visiting customer sites:
Preventive Maintenance Log
The sample below shows the DEFINITY Preventive Maintenance Log. Whenever
you complete any of the preventive maintenance procedures described in this
section, be sure to fill in the requested information on the log form before leaving
the customer’s premises.
Air Filters
Air filters should be inspected annually. If a filter is dirty or clogged, first tap it on
the ground. If the filter is still dirty or clogged, then wash it with warm water and a
mild detergent. A vacuum cleaner can be used if one is available. If there is no
facility for washing or vacuuming the air filter, then replace the filter (Comcode
407745009). Refer to ‘‘Fan and Filter Removal/Replacement’’
below for more
information on air filters and fans.
Fan and Filter Removal/Replacement
1. Remove the left door.
2. Remove the fan/filter access panel. See
Figure 1-3
.
DEFINITY csi Preventive Maintenance Log
Date System Installed: _________________________
Component
(Comcode)
Scheduled
Date
Completed
Date
Completed
By
Scheduled
Date
Completed
Date
Completed
By
Air Filter
1
(407745009)
1. Inspect annually; see ‘‘Air Filters’’ below for cleaning/replacement details.