Maintenance Objects
3-942PR-MAINT (Maintenance Processor)
3
Error Log Entries and Test to Clear Values
Notes:
a. The MTP Reset Test (#101) has failed.
b. The MTP Sanity Handshake Test (#106) has failed.
c. The MTP Analog Loop Around Test (#103) has failed.
d. The MTP Dual Port Ram Test (#104) has failed. An error of 769 with an aux
data of 5 indicates a hardware problem and testing will not clear it. The
circuit pack should be replaced.
e. The MTP Outpulse Relay Test (#102) has failed.
f. The MTP Manager I Loop Around Test (#228) has failed.
g. The MTP Aux Loop Around Test (#229) has failed.
NOTE:
Refer to the FAIL section of each test that fails for further instructions.
Table 3-406. Maintenance/Tape Processor Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
1
1. You must manually repeat the command with the "long" option the designated number of times from
the administration terminal or from a remote administration terminal because the Sanity Timer Test
(#83) logs you off.
0
2
2. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test processor a/b sh r 1
1 (a) Any MTP Reset Test (#101) MIN ON test processor a/b l r 3
257 (b) Any MTP Sanity Handshake Test
(#106)
test processor a/b r 2
513 (c) Any MTP Analog Loop Around
Test (#103)
MIN ON test processor a/b r 8
769 (d) Any MTP Dual Port Ram Test
(#104)
MIN ON test processor a/b l r 3
1025 (e) Any MTP Outpulse Relay Test
(#102)
MIN OFF test processor a/b r 5
1537 (f) Any MTP Manager I Loop Around
Test (#228)
MIN ON test processor a/b r 3
1793 (g) Any MTP Aux Loop Around Test
(#229)
MIN ON test processor a/b r 3