DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-2busyout access-endpoint
2
QUALIFIER is the last part of the command. It is 1 or more words or digits
used to further identify or complete the OBJECT. For example,
hunt group
15
or
station 3600
, where
15
and
3600
are qualifiers.
NOTE:
Qualifiers are printed in this typeface
.
An example of the command line required to add a station with extension number
1234
is
add station
1234
. In this example,
add
is the ACTION,
station
is the
OBJECT, and
1234
is the QUALIFIER. In the command line, spaces are required
between the ACTION, OBJECT, and QUALIFIER.
To save time, enter enough letters for each part of the command to make it
unique. For example, if you want to enter the command
change
system-parameters country-options
, typing
cha sys coun
is sufficient.
NOTE:
The craft login may not be allowed to perform some of the steps needed to
initialize the system. If access is denied to some of these procedures,
contact your Lucent Technologies representative for assistance.
Getting Help
Use the Help key for a list of options and the Cancel key to back out of any
command.
busyout access-endpoint
This command is destructive.
This command is used to busyout a specified
access endpoint.
Feature Interactions
If there is an active call on the specified access endpoint, the call to drop.
Action/
Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout
access-
endpoint
extension
Extension number of access
endpoint (per dial-plan)
Examples:
busyout access-endpoint 25012
busyout access-endpoint 77868
init
inads
craft
nms
none See below