DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-376CO-DS1 (DS1 CO Trunk)
3
k. Error Type 3840
Port Audit and Update Test (#36) failed due to an
internal system error. Enter the
status trunk
command to verify the status
of the trunk. If the trunk is out-of-service, then enter the
release trunk
command to put it back into in-service. Retry the test command. If the test
continues to abort, then escalate the problem.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order they are presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
NPE
Crosstalk Test,
for example, you may also clear errors generated from other tests
in the testing sequence.
NPE Crosstalk Test (#6)
One or more Network Processing Elements (NPEs) resides on each circuit pack
with a TDM Bus interface. The NPE controls port connectivity and gain, and
provides conferencing functions on a per-port basis. The NPE Crosstalk Test
verifies that this port’s NPE channel talks on the selected time slot and never
crosses over to time slots reserved for other connections. If the NPE is not
working correctly, one-way and noisy connections may be observed. This test is
usually only part of a port’s Long Test Sequence and takes about 20 to 30
seconds to complete.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
NPE Crosstalk Test (#6) X ND
Conference Circuit Test (#7) X ND
DS1CO Trunk Seizure Test (#314) X X ND
Port Audit and Update Test (#36) X X ND