DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-388CO-DS1 (DS1 CO Trunk)
3
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, an insane board is inserted, or the board is hyperactive (see Note
below).
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.
NOTE:
Hyperactivity causes some special problems with the sequence
suggested above. If the ports are translated after issuing the list
config command but the ’Vintage’ field reports that there is no board
(when there really is a board), then the busyout board and the
release busy board commands will not work (even though the reset
board command will work). The software will put the hyperactive
board back in service after the hyperactivity clears.
Table 3-170. TEST #314 DS1CO Dial Tone Seizure Test — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page