Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-156mark port
2
Summary report field descriptions
mark port
This command marks faulty ports as defective to prevent their use in other
administrative operations (for example, adding a data-module or station). Ports
on any type of circuit pack may be marked except for installed circuit packs that
are administered automatically (for example, Tone Detector, Tone Generator,
Announcement, Speech Synthesizer, Call Classifier and Maintenance/Test circuit
packs). If the port can be administered manually, and it is unassigned, the port is
marked as faulty. The
clear port
command reactivates the port. The
list
marked-ports command
displays marked ports in list format. All marked port
information is saved as part of translations.
Trk Grp Num
The trunk group number which is being summarized. Only
outgoing or two-way analog trunks will be listed.
Num Of Trks
The total number of members per trunk group.
Last Test Date
The date of the oldest measurement in the trunk group.
Last Test Time
The time of the oldest measurement in the trunk group.
Trunks Passed
Transm Test
The number of trunks that have passed the trunk transmission
tests.
Trunks Failed
Marginal Threshld
The number of trunks that failed a marginal threshold, but not an
unacceptable threshold according to the threshold values defined
on the trunk group form.
Trunks Failed
Unaccept Threshld
This is taken from the unacceptable threshold administered on the
Trunk group form.
Trks In-Use
The number of trunks that were in-use at the time of testing.
Trks Not Test
The number of trunks that were not tested due to error conditions.
Busied Out Trunks
The number of trunks that were busied out at the time. This could
be due to hardware problems, incorrect threshold values, etc.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
mark port
location
Location of the port to be marked:
PCSSpp
Examples:
mark port 1c0208
mark port 2a1001
init
inads
craft
none none