Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-183release journal-printer
2
Field descriptions
release journal-printer
This command activates maintenance objects associated with a specified
pms-log or wakeup-log link. Hardware tests are executed to verify that the
equipment is functioning. For general information on journal printer links, see the
description of the
‘‘busyout pms-link’’
command. For information on journal
printers, see the description of the
‘‘status journal-link’’
command.
Port
Port address (cabinet-carrier-slot-circuit) of the maintenance object
that is busied out or released, or the number of the data channel.
Maintenance Name
The type of maintenance object that is being busied out or
released.
Alt. Name
Alternate way to identify maintenance objects.
If the Object is The field contains
station extension
trunk
xxx/yyy
(where
xxx
= trunk group number
and
yyy
= member number)
private CO line
P/xxx
(where
xxx
= private CO line group
number)
Result
Test result: Pass, Abort, Fail
Error Code
System-generated description of a command failure.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
release
journal-printer
pms-log
wakeup-log
releases links to pms printers.
(1)
Releases links to wakeup
logging facilities. (0)
init
inads
craft
nms
none see below
release data-module 310
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C1103 DIG-LINE PASS
Command successfully completed