Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-131list mst
2
0x23 - MT_IMT (miscellaneous IMT hooks)
This message type is for miscellaneous IMT hooks. The only sub-type currently
available is for a debug button (dbut). The button number is provided in the
debug button MST message so that more than one button can be administered
(through IMT) to convey different meanings. For example, depression of button N
could signify the start of the problem symptoms, while depression of button N + X
could signify the end of the problem symptoms. Note that the button number
being logged represents the position of a button on a particular set type, and will
be different depending on set type and module type (feature, coverage, display,
and so forth). The mapping of the button number stored in the IMT_BUT_DEBUG
MST message to a position on the set is not trivial, however, the debug buttons
can be administered through TCM, debug button filtering enabled through TCM
and MST enabled using the ‘enable mst’ command and the resultant messages
sent to MST when each button is depressed can be examined for the button data
and noted.
Message format:
0x40 - internal message tracing of call_p, conn_m,
grp_m, serv_d, suser_m
Message formats: conn_m, grp_m, and suser_m:
serv_d (map-type messages):
Message[1] = 0x01 (debug button sub-type, IMT_BUT_DEBUG)
Message[2-3] = button number
Message[4-7] = user id
Message[1-4] = user identifier
Message[5-6] = hook identifier (defined in $BASEPJ/hdrs/mstencode.h)
Message[7+] = standard message (depends on hook type)
Message[1-4] = user identifier
Message[5-6] = hook identifier (defined in $BASEPJ/hdrs/mstencode.h)
Message[7] = STIM type
Message[8-11] = service identifier
Message[12] = port network number
Message[13] = endpoint number
Message[14] = angel number
Message[15] = circuit number
Message[16+] = message