DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-151ATM-EI (Expansion Interface Circuit Pack)
3
The problem is most likely
not
on the ATM-EI circuit pack reporting the
errors, but it could be due to one or more of the following reasons:
The fiber is not snugly connected to either the board or the ATM
switch.
The PN packet bus is corrupting the cells. See Packet maintenance
objects (Aux Data 35 only).
The fiber between the ATM switch and the ATM-EI is too long
(greater than 2km for multimode fiber). Use loopback to see if the
fiber is corrupting the cells.
Some other ATM-EI board is not receiving the cells properly.
The intervening ATM switch is dropping the ATM cells due to a
shortage of bandwidth, or the DEFINITY is using more than the
subscribed bandwidth.
Error Type 771: the ATM switch is sending cells with unknown VPI and VCI
address (wrong connection).
1. Ensure that the ATM-EI board address on the ATM switch matches
the ATM-EI (ATM) address on the DEFINITY side.
i. Error Type 1024-1151: These errors represent problems detected by the
ATM-EI board in response to SETUP and ADDPARTY requests from
software.
The Error Types and descriptions are in Table 3-63:
Aux Data values represent port network and angel numbers and
are in Table 3-64
.
Table 3-63. ATM Error Types 1024 - 1151
Error
Type Description General problem
1024 Next node unreachable
ATM protocol stack on
ATM-EI circuit pack
1056 DTL Transit not my node ID
Continued on next page