Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-977RING-GEN (Analog Ring Generator)
3
Notes:
a. Refer to EMG-XFER (Emergency Transfer) Maintenance documentation for
a description of this test.
b. Refer to EXT-DEV (External Alarm) Maintenance documentation for a
description of this test.
Analog Ring Generator Initialization Test (#117)
This test reports an error to the system software if the ringing voltage falls to low
(only if system software has made a request to the tone clock to monitor the
voltage). The Analog Ring Generator Initialization Test sends a request to the
active tone/clock.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
Analog Ring Generator Initialization Test (#117) X X ND
Analog Ring Generator Query Test (#118) X X ND
Single-Carrier Power Query Test (#79) X X ND
Emergency Transfer Query Test (#124) (a) X X ND
External Alarm Lead Query Test (#120) (b) X X ND
Table 3-430. TEST #117 Analog Ring Generator Initialization Test
Error
Code
Tes t
Result Description/ Recommendation
1
1000
1001
1003
1115
2012
2100
ABORT The system software is unable to determine the active tone/clock circuit
pack, unable to allocated the resources necessary to run the test, or unable
to send a down link message.
1. Wait for the green LED on the active tone/clock to go out; use the status
port-network command to determine the active Tone/Clock circuit
pack.
2. Rerun the test. If the test aborts again, refer to TDM-CLK Maintenance
documentation.
2000 ABORT Response to the request was not received within the allowable time period.
1. Look for TDM-CLK errors and alarms. Resolve all other Tone/Clock
problems first.
2. Rerun the test.
Continued on next page