Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-656ETR-PT (Enhanced Tone Receiver Port)
3
Notes:
a. There are two possible alarm levels for this error type: major alarm and
minor alarm. These alarm levels are dependent on the administered
thresholds for TTR, CPTR and CCTR. Each ETR port is capable of
operating an any of these.
A major alarm is raised if the total number of ports capable of TTR, CPTR
or CCTR detection currently in-service is less than or equal to 1/2 of the
administered TTR, CPTR or CCTR threshold number.
Otherwise, a minor alarm is raised. In either case, run the short test
sequence against the port (ETR-PT) and follow the error code procedures
for the individual tests.
The threshold number of ports for service is administered using the
change system-parameters maintenance
command.
1. Use
list configuration carrier
to get the board type and location. If
the board is TN744, then do Steps 2-4; if it is TN2182, do Steps
5-12.
2. Execute 3 commands:
busyout board UUCSS
,
reset board
UUCS
S, and
release board UUCSS
. Reset is required to reload
RAM associated with the TN744’s DSPs. This will take all 8 tone
detector ports out of service for a few seconds. Only 4 of the 8
would be out of service due to the alarm. (There are 4 tone
detectors on each of the two DSPs.) Other than the unlikely
potential of running out of tone detector resources in the switch,
there is no other effect when the board is reset.
3. Test the board (
test board UUCSS long
).
4. If the test passes, terminate the repair process. If the test fails,
replace the board.
5. Check to see if the board is duplicated (
list cabine
t and
status
port-network
on the affected port network.)
6. If the board is not duplicated, use test tone UUCSS long to resolve
the error. The long test resets the board and is required to reload
on-board RAM associated with the TN2182”s DSPs. The effect is
that tone detectors are taken out of service momentarily and tones
are removed from the TDM bus for about 10 seconds. This means
513 (c) any Tone Detection
Verification Test (#42)
MAJOR/
MINOR (a)
ON test port PCSSpp r 3
Table 3-272. Enhanced Tone Receiver Port (ETR-PT) Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page