Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1176UDS1-BD (UDS1 Interface Circuit Pack)
3
1314(r) Any Far CSU Loopback Test
(#1213)
MIN/WRN
3
OFF test ds1-loop UUCSS
end-loopback/span-test
1320 Any Loss of Signal Alarm
Inquiry Test (#138)
MIN/WRN
3
OFF test board UUCSS
1321 Any Loss of Signal Alarm
Inquiry Test (#138)
MIN/WRN
3
OFF test board UUCSS
1322 Any Loss of Signal Alarm
Inquiry Test (#138)
MINOR ON test board UUCSS
1323 Any Loss of Signal Alarm
Inquiry Test (#138)
MIN/WRN
3
OFF test board UUCSS
1324 Any Loss of Signal Alarm
Inquiry Test (#138)
WARNING OFF test board UUCSS
1537(s) 46082 MIN/WRN
3
ON
1538(t) Any MIN/WRN
3
ON
1793 Any Blue Alarm Inquiry Test
(#139)
MAJ/MIN/W
RN
4
OFF test board UUCSS
1794 Any Blue Alarm Inquiry Test
(#139)
MAJ/MIN/W
RN
4
OFF test board UUCSS
1795 Any Blue Alarm Inquiry Test
(#139)
MAJ/MIN
/WNG
4
OFF test board UUCSS
2049 Any Red Alarm Inquiry Test
(#140)
MIN/WRN
3
OFF test board UUCSS
2305 Any Yellow Alarm Inquiry
Test (#141)
MIN/WRN
3
OFF test board UUCSS
2306 Any Yellow Alarm Inquiry
Test (#141)
MIN/WRN
3
OFF test Board UUCSS
2561 Any Major Alarm Inquiry Test
(#142)
MIN/WRN
3
OFF test board UUCSS
2817 Minor Alarm Inquiry Test
(#143)
MIN/WRN
3
OFF test board UUCSS
3073 to
3160 (u)
Any Slip Alarm Inquiry Test
(#144)
MIN/WRN
3
OFF test board UUCSS r 6
3330(v) 46083 MIN/WRN
3
ON
3585 to
3601 (w)
Any Misframe Alarm Inquiry
Test (#145)
MIN/WRN
3
OFF test board UUCSS r 6
3840(x) Any None
Table 3-513. DS1 Interface Circuit Pack Maintenance Error Log Entries — Continued
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
Continued on next page