Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-123ATM Tips
1
Figure 1-51. A500: show stats sonet a1.2 screen
Ensure that the fields have the values indicated below.
Receive Cell
Count
Each field’s values should be increasing if the TN230X is
actively sending and receiving cells with the A500. (Even if
a TN230X did not achieve board insertion, it will still try to
talk to the A500.)
Transmit
Cell Count
If neither field is increasing, the A500 port may have been
marked down using the admin down command. Use the
show system interfaces command to verify that the Admin
Status is up.
If the Receive Cell Count is increasing but the
Transmit Cell Count is not increasing, this may be
because the port was administered with no UNI signaling
(admin link command). Use the show signaling summary
command to ensure that Signaling is UNI3.1.
The error counters may not be zero, but should not be large
either compared to the receive and transmit cell counters. If
the counters are large and increasing, check the fiber
integrity. Make sure the fiber pairs are securely plugged into
both the TN230X and the A500.
If the fiber has been pulled and reinserted as part of fault
diagnosis, the non-zero Loss of Signal Err counter
may be correct.
Sonet per Port Statistics
---------------------------------
Receive Cell Count: 80654
Transmit Cell Count: 79555
Section Level Bit Err: 1
Line Bit Err: 1
Line FEB Err: 168
Path Bit Err: 1
Path FEB Err: 98
Correctable HCS Err: 0
Uncorrectable HCS Err: 0
Loss of Frame Err: 1
Loss of Signal Err: 0
Out of Frame Err: 0
Path Signal Label: 19