DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-863OPS-LINE (DS1 OPS Line)
3
1005 ABORT Test failed due to incompatible configuration administered in station
administration.
1. Verify the station administration is the station assigned to Port 24 of the
DS1 Interface circuit pack while common channel signaling is specified.
1006 ABORT The test was aborted because the station is out of service. This condition may
be accompanied by an error type 18 entry in the error log. You may want to
determine why the station was taken out of service. (When stations are taken
out of service by maintenance software, the problems that led up to that must
be cleared.)
1. Use the status station command to check the state of the port. If the port
is indeed out of service, enter the release station command to bring the
station back into service.
2. Retry the command at 1-minute intervals a maximum of 5 times.
3. If the test continues to abort, and the station is in the in-service/idle state,
escalate the problem.
1020 ABORT The DS1 Interface circuit pack is out-of-service.
1. Look for DS1-BD errors in Hardware Error Log. If present, refer to the
DS1-BD (DS1 Interface Circuit Pack) Maintenance documentation.
2. Retry the command.
2000 ABORT The test was aborted because response to the test was not received within
the allowable time period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. If the test aborts with error code 2000 again, run short test sequence on
the associated DS1-BD or UDS1-BD. If tests 138 through 145 on the
associated DS1-BD or UDS1-BD are also aborting with error code 2000,
hyperactivity on the board or facility is indicated. In this case, the
hyperactivity problem should be dealt with first.
2012 ABORT The test was aborted due to a system error.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1 FAIL Internal System Error.
1. Look for DS1-BD errors in the Hardware Error Log. If present, refer to the
DS1-BD (DS1 Interface Circuit Pack) Maintenance documentation.
2. If a channel multiplexer is used as the remote DS1 endpoint to which the
station connects, refer to the multiplexer vendor’s maintenance document
for diagnosis.
3. Retry the command at 1-minute intervals a maximum of 5 times
Table 3-374. TEST #312 DS1OPS Switchhook Inquiry Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page