DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-835MMI-BD
3
Error Log Entries and Test to Clear Values
Notes:
a. The circuit pack stopped functioning or it was physically removed from the
system. The alarm logs approximately 11 minutes after the circuit pack
has been removed and/or the SAKI Sanity Test (#53) fails.
If the circuit pack is in the system and the red LED is on, follow the
instructions for a red alarm in ‘‘Control Circuit Packs’’
in ‘‘Maintenance for
csi systems’’.
b. This circuit pack has been busied out using the
busyout board PCSS
command.
c. There are more than four MMI circuit packs in the system. Remove the
circuit pack that generated the error in the error log by locating the slot
indicated by the error.
d. Indicates transient communication problems between the switch and this
circuit pack. Execute the
test board PCSS
command and refer to the
repair procedures for the Control Channel Looparound Test (#52) in the
XXX-BD section.
Table 3-361. MMI-BD Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If all tests pass, run the long test sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test board PCSS sh r 1
1 (a) Any None MIN ON
18 (b) 0 Busyout board PCSS WNG OFF release board PCSS
217 (c) 0 None WNG ON
257 (d) 65535 Control Channel Loop Test (#52) MIN ON test board PCSS r 3
513 (e) 4352
to
4357
Uplink error from pack
769 (f) Any MMI Synchronization Status
Test (#1123)
None
1281 (g) Any Circuit Pack Restart Test (#594) MAJ ON
1538 (h) Any Software detected error MIN ON
1793 (i) ANY TSI XTalk (#6) MIN ON test board PCSS l r 3
2049 (j) Any TSI Loop (#1108) MAJ ON test board PCSS l r 3