DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-396CO-TRK (CO Trunk)
3
Notes for Table 3-172:
1. At the administration terminal, busyout the affected port, and run a Long
Test Sequence. Observe the test results. If any tests fail, refer to the
description of the tests and the associated error codes. Release the port.
If users continue to report troubles, check for other errors and make test
calls to determine whether the problem should be escalated or referred to
the CO.
2. At the administration terminal, busyout the affected port, and run a Long
Test Sequence. If Dial Tone Test #0 passes, ignore this error. Release the
port.
3. At the administration terminal, busyout the affected port, and run a Long
Test Sequence. If CO Demand Diagnostic Test #3 passes and this error
keeps occurring, refer problems to CO. Release the port.
4. If the error count associated with this error type is very high (that is, 255)
and all tests pass, then either the reverse current detector is defective or
the CO line is noisy. If the CO line is suspected, Tip and Ring observations
should be made. If the line is determined to be noisy, the problem should
be referred to the CO. If the reverse current detector is defective, ignore
this error.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order they are presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
NPE
Crosstalk Test,
for example, you may also clear errors generated from other tests
in the testing sequence.
3585 57424 No loop current on outgoing call. This error
occurs on attempt to seize a loop or
ground-start trunk for an outgoing call. An
error occurs if loop current is not detected or
the caller hangs up before it is detected.
See Note 3 at end of table.
Table 3-172. CO Trunk Errors with NO Tests — Continued
Error
Type
Aux
Data Description and System Action System Technician Action
Continued on next page