DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-420DATA-BD (Data Channel Processor Circuit Pack)
3
Notes:
a. This error indicates the DATA-BD portion of the Processor circuit pack
stopped functioning. Since the Processor circuit pack cannot be reset via
the
reset board PCSS
command, the Data Channel Reset Test (#107) in
the Long Test Sequence for the DATA-CHLs must be used to reset it as
follows:
1. Issue the
list data
command to determine if one, or more, Data
Channels (DATA-CHLs) is administered.
NOTE:
A Data Channel (DATA-CHL) is identified by a "type" value of
"netcon."
2. If a Data Channel (DATA-CHL) is not administered, use the
add
data-module [<ext> | next]
command to administer a DATA-CHL.
3. From the form resulting from the
list data
command, choose a Data
Channel (DATA-CHL).
4. Issue the
test data-module <ext> long
command using the
extension for the DATA-CHL chosen in Step 3.
!
WARNING:
Issuing this command drops all data channel extensions. See
DATA-CHL (Data Channel) Maintenance documentation first.
769 (e) 4358 None
1025 (f) 4363 NPE Audit Test (#50) test network-control [a | b]
sh
1538 (g) Data Channel Reset
Test (#107)
MINOR ON test data-module <ext> l
3840 (h) Any None
3999(i) Any None
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 3-180. Data Channel Processor Circuit Pack Error Log Entries — Continued
Error Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page