Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-319test alarms
2
Output
The following example shows the output from the
test alarms
command (query
form left empty by pressing
ENTER). The responses display on a test-by-test basis
with one line of data for each test result.
Field descriptions
When encountering errors in preparing a particular object to be tested (not
inserted, contention, etc.), an error message display in the
TEST RESULTS
section of the output form.
ALARM ENTRY
section
Port
Port location of alarmed object (cabinet-carrier-slot-circuit); same
identifier as alarm log
Maintenance
Name
The name of the maintenance object
On Board
Fault detected is on the associated circuit pack (
y
) or off board
(
o
).
Alt Name
Terminal extension numbers or trunk group numbers
Alarm Type
Major, Minor, or Warning
Service State
Current service state of the station and trunk ports:
RDY
(ready for
service),
OUT
(out of service), or
IN
(in service).
Ack
Whether alarm has been acknowledged by the first and second
OSS telephone numbers, respectively.
test alarms Page 1
ALARM ENTRY
Port Maintenance On Alt Alarm Svc Ack? Date Alarm
Name Brd? Name Type State 1 2 Alarmed Count
01C03 UDS1-BD n WARNING 03/06/16:48 1/4
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C03 UDS1-BD 138 NO BOARD
01C03 UDS1-BD 139 NO BOARD
01C03 UDS1-BD 140 NO BOARD
01C03 UDS1-BD 141 NO BOARD
01C03 UDS1-BD 142 NO BOARD
01C03 UDS1-BD 143 NO BOARD
01C03 UDS1-BD 144 NO BOARD
01C03 UDS1-BD 145 NO BOARD
01C03 UDS1-BD 146 NO BOARD
Testing completed for this object.