DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-330test customer-alarm
2
test customer-alarm
This command performs hardware diagnostic tests on the leads of the Processor
and EPN maintenance circuit packs, used for customer-provided alarms by
closing the appropriate relay for 1 minute. Failure is verified by checking the
customer alarm attached to the specified circuit pack.
Defaults
The default cabinet is cabinet 1, and the default carrier is “a.” The default for the
remaining parameter is a repeat of 1.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test
customer-alarm
location
short
long
repeat
number
clear
schedule
Extension of the data module or
data channel to be tested (per
dial-plan)
Runs test number 115
Runs test number 115 (same as
short test option)
How many times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.
1
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.
2
Examples:
test customer-alarm
test customer-alarm schedule
test customer-alarm 02 r 2
test customer-alarm 01b r 25
test customer-alarm 01b r 25
schedule
test customer-alarm 2a
test customer-alarm 2a sh
test customer-alarm 01b l
schedule
test customer-alarm 3 c
1 If no alarms are registered against the maintenance object then the test sequence is run only once. The
long clear
option forces a clear of all alarms if no errors are encountered during testing. The
short clear
option only clears
alarms pertinent to tests in the short sequence.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
See
below
none