Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-37clear errors
2
Feature Interactions
Status audits
displays data cleared by the
clear audits
command. After
clear
audits
executes successfully, the
display audits cumulative
and/or
display
audits peak-hour
commands display information collected since the last
clear
audits
command. The start date displays on the status audits screen reflecting
the time that
clear audits
executed.
clear errors
The
clear errors
command moves errors and resolved alarms to cleared-error
lists, making room for new incoming error messages. This command does not
clear active alarms from the alarm log. This command must be used with care to
prevent overwriting cleared entries. When additional entries are needed to log
new errors, the system clears error entries first. Use the
display errors
command
to list the cleared errors.
clear interface
The
clear interface
command reintializes counter values maintained by the
Processor Interface (PI) circuit pack. The
status interface
command, used in the
development environment, displays the counters. The PI circuit pack, a front end
processor, implements the packet and link layers of the BX.25 protocol, and the
ISDN procedure-D protocol.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
clear audits
cumulative
peak-hour
Clears data collected about the
peak hour since the last reboot
or
clear audits cumulative
command
Clears peak hour data
Examples:
clear audits cumulative
clear audits peak-hour
init
inads
none See below
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
clear errors
Examples:
clear errors
init
inads
craft
none none