DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-406CO-TRK (CO Trunk)
3
Table 3-176. TEST #33 Loop Around and
Conference Circuit Test
Error
Code
Tes t
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
7 ABORT Conference Circuit Test aborted.
129 ABORT The 404-Hz reflective loop around test aborted. Response to the test request
was not received within the allowable time period.
131 The 1004-Hz reflective loop around test aborted. Response to the test request
was not received within the allowable time period.
133 The 2804-Hz reflective loop around test aborted. Response to the test request
was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call. Use the display port PCSSpp command to determine
the trunk group/member number of the port. Use the status trunk command
to determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait until
the port is idle before retesting.
1. If the port status is active but the port is not in use (no calls), check the
error log for error type 769 (see the Error Log table for a description of
this error and required actions). The port may be locked up.
2. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Refer to TDM-BUS Maintenance to diagnose any active
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, repeat
test at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized force.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR-LEV
Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT
Maintenance documentation.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 5 times.