DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-22change synchronization
2
Field descriptions
change synchronization
Each system contains a hierarchy of sources used for timing synchronization.
DS1 inputs to the external stratum 3 clock affect stratum 3 synchronization
hierarchy. Primary and secondary fields reflect Stratum 4 synchronization. If all
fields are blank, the tone clock board within each PN provides timing for that PN.
Output/Input
The following example shows the output for the
change synchronization
command. “4” was entered in the stratum field.
Cabinet
Administered cabinet number
Cabinet Layout
Type of cabinet (single-carrier)
Carrier
In-use cabinet carrier
Carrier Type
Carrier function (port, processor, or expansion control)
Slot
Slot numbers (0 - 21).
Code
Circuit pack code (TN number) to identify the circuit pack type
Sfx
Lists the suffix, if applicable
Name
Alphanumeric circuit pack name
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
change
synchronization
Examples:
change
synchronization
change synch
init
inads
craft
cust
rcust
bcms
none DS1 interface, BRI
trunk, or UDS1 board
selected as either a
primary or secondary
synch source cannot
be removed on the DS1
circuit pack
administration form or
the regular circuit pack
administration form.