Maintenance Commands
2-338test environment
2
3. EXT-DEV tests external (AUDIX, for example) alarm status for both the
SCC and MCC cabinet systems.
4. RING_GEN tests ringing voltage are tested in MCC cabinets only.
NOTE:
The processor carrier is not be recycled. All port carriers are recycled, and
service is interrupted for each port carrier. If a carrier containing an active
tone-clock board is recycled, all ports in the cabinet or port network will
have service disrupted.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test environment
location
short
long
repeat
number
clear
schedule
Cabinet 1 = PPN
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.
1
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.
2
Examples:
test environment
test environment schedule
test environment 1 sh
test environment 1 l r 25
test environment 01 l r 25
test environment 01 l r 25
schedule
test environment 2 l c
test environment 3 c
1 If no alarms are registered against the maintenance object then the test sequence is run only once. The
long clear
option
forces a clear of all alarms if no errors are encountered during testing. The
short clear
option only clears alarms pertinent
to tests in the short sequence.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
Cabinet = 1;
test sequence
= short; repeat
= 1
See below