Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-918PMS-LINK (Property Management System Link)
3
for five minutes before attempting to set up the link again. If this error type
recurs frequently (that is, more than once a month), advise the customer to
call the vendor of the PMS to check out the PMS device. Once the PMS
Link is successfully established, this error disappears from the Hardware
Error Log (see Note).
NOTE:
The PMS should be checked for adherence to message rate defined
in the PMS/PBX protocol specifications. No alarm is raised against
this error.
i. The attempt to swap the database between PBX and PMS failed 3 times
consecutively due to excessive PMS/PBX protocol violations, buffer
overflows, or PMS Link outages. The PMS Link is NOT torn down. If this
error type recurs frequently (that is, more than once a month), then advise
the customer to call the vendor of the PMS to check out the PMS device.
Once the PMS Link is successfully established, this error disappears from
the Hardware Error Log. No alarm is raised against this error.
j. The PMS Link has been busied out for system technician-demanded
maintenance via the
busyout pms-link
command or has been brought
down via the
test pms-link long
command. The PMS Link is torn down,
and PMS Link maintenance stops attempting to reestablish the link in the
case where the
busyout pms-link
command has been used. When the
test pms-link long
command has been used, PMS Link maintenance
continues to try to reset the link. To restore the PMS Link after use of the
busyout pms-link
command, issue the
release pms-link
command. To
restore the PMS Link after use of the
test pms-link long
command, issue
the
test pms-link
command.
k. The PMS Link is physically established, but the protocol has not been
started by the PMS before the protocol timer expires. The PMS Link is NOT
torn down. If this error type recurs frequently (that is, more than once a
month), advise the customer to call the vendor of the PMS to check out the
PMS device. Once the PMS Link is successfully established, this error
disappears from the Hardware Error Log.
NOTE:
The PMS should be checked to make sure that it attempts to start the
protocol according to the PMS/PBX protocol specifications. No
alarm is raised against this error.