DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-297BRI-SET, ASAI-ADJ, BRI-DAT
3
l. Certain ASAI protocol-specific cause codes are logged by switch
software. The cause code can be determined from the following formula:
If the error type is greater than 3712, then the ASAI cause code is equal to
the error type minus 3712. This code was sent to the adjunct by the
switch.
If the error type is less than 3712, then the ASAI cause code is equal to the
error type minus 3584. This code was sent to the switch by the adjunct.
A description of the various ASAI cause values is contained in the Table
10-64. This table also contains recommended system technician actions
associated with the cause value. Further information can also be found in
the Lucent ASAI Specification (288-500-03). In addition, the Aux Data field
of the Error Log entry contains additional diagnostic information.
Table 3-130. ASAI Cause Values
Code Explanation Recommendation
Service or Option
Not Available
0 Unrecognized
ASAIProtocol
Operation
Requested ASAI protocol operation is not
implemented by the switch or adjunct. Aux Data
field of Error Log entry contains protocol identifier
for unrecognized operation.
1. Consult switch and adjunct documentation to
determine which set of operations is supported
by the switch and the adjunct. Adjunct
administration turning off operations not
implemented by the switch may resolve the
problem.
40 Resources not
available
No available internal resources to service switch or
adjunct request. System transaction capacity for
adjunct or switch is exceeded.
1. Re-engineering of adjunct services my be
required.
Continued on next page