Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-343test hardware-group
2
Setting the Test Parameters
Once the user has entered the desired action (
test hardware-group
) and the
object (board, carrier, etc.), then an options form displays.
Field descriptions
Test
sequence
Short
(nondestructive) or
long
(more comprehensive, still
nondestructive) test sequence
Test
Repetition
repeat
- (1-99) each test is executed the number of times specified on
each physical object.
continuously
-all tests on all the specified hardware run until
cancelled by either pressing the
CANCEL key or by executing the
cancel hardware-group
command.
count:
Repeat test sequence value (1-99). If the
Test sequence
field is set
to
continuously
, then this field disappears from the screen; if this field
is set to
repeat
, then the field appears.
Auto-page?
Provides a new screen every time the SAT screen fills with test results.
(
n
/
y
). The screen does not scroll to accommodate new results;
instead a new screen is provided after the current screen fills up.
If the
auto-page
option is not selected, the SAT screen does not
refresh once it is filled, and testing stops until the user enters the
PAG E
key to continue or the
CANCEL key to cancel the testing.
This option is not allowed if the
background
option is selected.
test hardware-group system Page 1 of 1
TEST HARDWARE-GROUP SELECTIONS
Select the desired options for the specified test.
Test sequence: short
Test repetition: repeat count: 1
Output OPTIONS: HARDWARE OPTIONS:
Auto-page? n
All-ports? n
Background? n SPE-interchange? n
Failures? n