DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-9How to use the Maintenance book
1
11. Type
test port 01C1008 long
and press Enter.
“01C1008” is the address of the alarmed port (see
Screen 1-2
and
Screen
1-3)
12. While the port test is running, look up the Error Type (1537 from
Screen
1-3) in the DID Trunk Error Log Entries table (example below).
13. Since the Test to Clear Value (
test port 01C1008 sh r 1) is very similar to the
initial test you ran in Step 11, wait for the results of the port test.
14. When the port test finishes, the following display appears (
Screen 1-4
):
Screen 1-4. Test Results screen
15. Find the Port Diagnostic Test (#35) [from the
Test No.
field) in the
DID-TRK section of the Maintenance book. Note the
Error Code
(61472).
16. Look in
Table 1-3
for Test #35 and then find “61472” in the Error Code
column
and
“FAIL” in the Test Result column read the
Description/Recommendation column.
2. A MAJOR alarm on a truk indicates that alarms on these trunks are downgraded by the set options
command and that at least 75% of the trunks in this trunk group are alarmed.
Table 1-2. DID Trunk Error Log entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
1537 Port Diagnostic
(#35)
MAJ/MIN/
WRN
OFF test port UUCSSpp sh r 1
3840 (k) 40965 None
Continued on next page
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C1008 DID-TRK 35 FAIL 61472