DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-963PRI-CDR/SEC-CDR (PRI-CDR Link)
3
If the destination is "eia," then look for PR-MAINT errors in the Hardware
Error Log. If present, refer to ‘‘PR-MAINT (Maintenance Processor)’’
Maintenance documentation.
4. Is a data channel on the TN798 Processor circuit pack in the
in-service/idle state?
Enter
list data
command and find out the extension numbers of data
channels. Enter
status data extension
command and make sure that at
least one data channel is in the in-service/idle state. If no data channel is
available, then look for DATA-CHL/DATA-CON/DATA-BD errors in the
Hardware Error Log. If present, refer to ‘‘DATA-BD (Data Channel
Processor Circuit Pack)’’.
5. Is the external CDR output device available?
Make sure that the CDR output device is on-line and ready for service.
Check the physical connectivity between Data Module and the CDR
output device or between the EIA port on backplane of the switch and the
CDR output device.
It is recommended to busy out the CDR link before executing maintenance tests
over the CDR link. If the CDR link is busied out, then all CDR link maintenance
actions are deactivated. The interference to tests of other MO is off.
Error Log Entries and Test to Clear Values
Table 3-420. CDR Link Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
1
0
2
0 Any Any Any test cdr-link
primary|secondary sh
18 (a) 0 busy out cdr WARNI
NG
OFF release cdr-link
primary|secondary
primary | secondary
25 (b) 0
3 to 6
9
99
255
Link Retry Test (#215) MINOR/
WARNI
NG
3
OFF test cdr-link
primary|secondary l
513 (c) 0
3 to 6
9
test cdr-link
primary|secondary
Continued on next page