DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-239status cleared-alarm-notif
2
status cleared-alarm-notif
Expert Systems use this command to detect chronic alarming conditions. If this
command displays
Feature is suspended
, Expert Systems can identify open
trouble tickets as chronic problems for special consideration.
status conference
Use this command to solve the following multimedia problems:
1. A user cannot join or remain connected to a conference.
2. Automatic algorithms — audio AUTO mode and the Px64 video picture
specifications downgrade the conference, causing poor video quality.
3. A user does not receive full service.
4. An audio add-on user cannot join or remain connected to a conference.
5. A conferee is not seen by other users due to interworking problems.
6. Users cannot participate in Multipoint Communications Service
conferences.
7. Continuous conferences do not move endpoints in or out of quadrants.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
cleared-alarm-
notif
1
2
First OSS telephone number
status of Cleared Alarm
Notification.
Second OSS telephone number
status of Cleared Alarm
Notification.
init
inads
craft
cust
rcust
First OSS
telephone
number for
the Cleared
Alarm
Notification
status.
none
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status
conference
status
conference
status
conference
2 print
Stored conference data.
Conference 2 data (current
or last completed). Sends
report to printer.
init
inads
craft
Conference-
ID =
all
(all
stored data).
none